World Congress on Medical Physics and Biomedical Engineering September 7 - 12, 2009 Munich, Germany

;

324,98 €
308,73 €
AGGIUNGI AL CARRELLO
TRAMA
Present Your Research to the World! The World Congress 2009 on Medical Physics and Biomedical Engineering – the triennial scientific meeting of the IUPESM - is the world’s leading forum for presenting the results of current scientific work in health-related physics and technologies to an international audience. With more than 2,800 presentations it will be the biggest conference in the fields of Medical Physics and Biomedical Engineering in 2009! Medical physics, biomedical engineering and bioengineering have been driving forces of innovation and progress in medicine and healthcare over the past two decades. As new key technologies arise with significant potential to open new options in diagnostics and therapeutics, it is a multidisciplinary task to evaluate their benefit for medicine and healthcare with respect to the quality of performance and therapeutic output. Covering key aspects such as information and communication technologies, micro- and nanosystems, optics and biotechnology, the congress will serve as an inter- and multidisciplinary platform that brings together people from basic research, R&D, industry and medical application to discuss these issues. As a major event for science, medicine and technology the congress provides a comprehensive overview and in–depth, first-hand information on new developments, advanced technologies and current and future applications. With this Final Program we would like to give you an overview of the dimension of the congress and invite you to join us in Munich! Olaf Dössel Congress President Wolfgang C.

SOMMARIO
Is the MOSFET Dosimeter Feasible at Diagnostic X-Ray Energies for Interventional Radiology?.- Doses to Patients from Photo-Neutrons Emitted in a Medical Linear Accelerator.- Correlation between Radiation Sensitivity and Body Weight.- Simulation of Human Eye for Ophthalmic Brachytherapy Dosimetry Using MCNP-4C Code.- Radioprotective Effects of Hesperidin against Genotoxicity Induced by Gamma Irradiation in Human Lymphocytes.- Iranian doctor’s knowledge about received dose by patients in diagnostic radiology.- Biological Effect of Single, Very Large Dose Fractions as Used in Intraoperative Radiotherapy (IORT).- Molecular Mechanisms of Radiation-Induced Second Cancers.- Diagnostic Reference Levels in Computer Tomography at IPOCFG, EPE.- Estimation of External Natural Background Gamma Rays Doses to the Population of Caspian Coastal Provinces in North of Iran.- Patient Dosimetry and Image Quality in Conventional Diagnostic Radiology: A Practical Optimization Experience from a Serbian Hospital.- The Effect of Spatially Nonuniform Electromagnetic Field and Antitumor Drug on Growth of Maglinant Tumor.- Prevention of Overexposure by Means of Active Protective Reactions and Magnitude of Temporary Blinding from Visible Laser Radiation.- Dose Distribution in Pediatric CT Abdominal Examination: Phantom Study.- Ionization Effects Produced by Neutron Interaction Products in BNCT Field.- Criteria for Acceptability for Radiological, Nuclear Medicine and Radiotherapy Equipment – Part 4: Nuclear Medicine Equipment.- Criteria for Acceptability for Radiological, Nuclear Medicine and Radiotherapy Equipment – Part 3: Radiotherapy Equipment.- Half-Value Layer Measurement for Effective Energy, Using Radiochromic Film and Step-Shaped Aluminum Filter.- Influence on Erythropoiesis and Blood Catalase Activity Low Intensity Electromagnetic Millimeter Radiation.- Quality Assurance in Digital Volume Tomography.- Dicom Dose: CAPTURE AND REPORTING.- CT Quality Assurance Protocol and Its Validation in Various Ministry of Health Hospitals in Oman.- Precise Mapping of Skin Dose to Avoid Further Radiation-Induced Epilation.- The Comparative Analysis of Various Methods of CT Effective Doses Estimation.- Criteria for Acceptability for Radiological, Nuclear Medicine and Radiotherapy Equipment – Part 1: Introduction and Methodology.- Radiation Exposure to Critical Organs in Orthopantomography.- First Report of Radiation Dose to Pediatric Patients Arising from Diagnostic Chest and Abdomen Examination.- Dental Treatment with Fluoride at Various Stages of Tumor Therapeutic Irradiation.- Electron Absorbed Fractions in Skeletal Soft Tissues Based on Red Bone Marrow Segmentation at Runtime in ?CT Images of Human Trabecular Bone.- Patient Dose Reduction in Some Routine Radiographic Examination in Iran.- A Study of Maternal and Foetal Doses Arising from V/Q and CTPA Scanning during Pregnancy.- Study and Analysis of Radiation Level at Different Hospitals in Nepal.- Radiation Protection in Cardiac Catheterization Laboratories: Non-shielded Parts of the Body Contribute Significantly to the Effective Dose of the Operator.- Calculation of Normalized Organ Doses for Pediatric Patients Undergoing CT Examinations on Four Types of CT Scanner.- Preview of a Series of Adult Human Phantoms for Radiation Protection Dosimetry.- Optical Enhancement of DNA-Base Radio-Resistivity.- Radiology Workload Analysis – Role and Relevance in Radiation Protection in Diagnostic Radiology.- Use of Active Personal Dosemeters in Interventional Radiology: A Systematic Study in Laboratory Conditions.- Diagnostic Reference Levels in Cardiology and Interventional Radiology.- Compensator for Advanced Radiation Field Homogeneity.- Differences in Gamma-H2AX Foci Formation after Irradiation with Continuous and Pulsed Proton Beams.- Diagnostic Reference Levels in Computed Tomography in Switzerland.- A New Method to Measure Shielding Properties of Protective Clothing Materials.- Radiation Response of Normal Tissues and Tumors to Carbon Ion Irradiation.- The Impact of the 2007 Recommendations of the International Commission on Radiological Protection (ICRP) in Medical Applications.- Estimation of Patient Doses from Interventional Radiology Procedures in Pakistan Result of IAEA Project RAS /9/047.- Inhibiting Survivin Expression Increases the Radiosensitivity of Human Hepatoma HepG2 Cells to High-LET Carbon Ions.- Extremity and Eye Lens Doses of the Staff during Interventional Radiology Procedures – First Results.- GafChromic® Film Measurements for Microbeam Radiation Therapy (MRT).- Application of the New ICRP Reference Phantoms to Internal Dosimetry: Calculation of Specific Absorbed Fractions of Energy for Photons and Electrons.- Dose-Area-Product to Effective Dose in Interventional Cardiology and Radiology.- The Reference Computational Phantoms Adopted by ICRP and ICRU.- Indoor Radon Measurement in Some Apartments of Mashhad City (Iran).- Mammodos – In-Vivo Dosimetry in Mammography.- Investigation of the Specific Absorption Rate for a 7 Tesla T/R Body Array.- Lessons Learned from 25 Years in Exploring Norwegian Radiology Practices from a Radiation Protection Point of View.- Calibration of Semiconductor Detectors for Dosimetry in Diagnostic Radiology.- Charge Recombination Correction in the Dosimetry by Means Ionization Chambers of a High Dose-per-Pulse Electron Accelerator for Intraoperative Radiation Therapy (IORT).- Doses to Patients in Interventional Cardiology.- Criteria for Acceptability for Radiological, Nuclear Medicine and Radiotherapy Equipment – Part 2: Radiology Equipment.- TL Response Study at Dosimetry of 106 Ru/Rh Ophthalmic Applicator.- The Exposure Assessment of Pulsed Magnetic Fields – A Comparison between Physiological Backgrounds and Guidelines.- Accelerated Hypo-Fractionation by Biological Equivalent DVH for Patients Affected by Gastric Carcinoma in Postoperative Concomitant Radiochemotherapy.- Reducing Non-uniformity Error of Radiochromic Film in the Diagnostic Range by Ultraviolet Exposure: Preliminary Study.- Investigation of Acceptance Criteria for the gamma-index in Scanned Carbon Ion Radiotherapy.- Feasibility of Polycrystalline Alanine-in-Glass Tubes as Gamma-Ray Dosimeters.- The Risk for Secondary Cancers in Patients Treated for Prostate Carcinoma – An Analysis with the Competition Dose Response Model.- Evaluating the Dosimetric Effect of Lack of Side-Scatter Volume for Measurements of Large Fields with an Integration Diode Array.- Radon Measurement in Drinking Water Samples of Mashhad City in Iran.- Water-Equivalent Calibration of 192 Ir HDR Brachytherapy Source using MAGIC Gel Polymer.- Doses to patients for computed tomography in Sarajevo.- Biological Effects of Densely Ionizing Radiation.- Track Structure and Biological Effects of Densely Ionizing Radiation.- Patient Radiation Doses during Cardiac Angiography and Implantations of Cardiac Resynchronization Devices. Deriviation of Local DRLs.- Protection of Human Health and the Environment by Means of Predisposal Management of Medical Solid Radioactive Waste.- The Effect of Activated Water on Staphylococcal Infection in Vivo in Animal Model and in Vitro on Staphylococcus Aureus Culture.- Evaluation of SAR in a Finite Element Human Body Model Imposed to Magnetic Fields Generated by a MRI Bird Cage Coil.- Exploring the Use of the Tarmed Coding System for Establishing the Annual Frequency of Medical x-Ray Examinations in Switzerland.- Simulation of Beta-Emitters for Radiopharmaceutical Dosimetry using Voxel Phantoms and Monte Carlo Calculations.- Characterization of a Radiochromic Solid Polymer Dosimeter According to Its’ Composition.- Radiosensitizing Effect of IUdR Combined with Co-60 ? Radiation on Malignant Glioma Spheroids.- The Use of Radiobiological Parameters and the Evaluation of NTCP Models. How Do They Affect the Ability to Estimate Radiation Induced Complications?.- Simulating Dose and Cancer Risk due to Low-Dose Neutron Background in Proton Beam T

ALTRE INFORMAZIONI
  • Condizione: Nuovo
  • ISBN: 9783642039010
  • Collana: IFMBE Proceedings
  • Dimensioni: 297 x 210 mm Ø 3741 gr
  • Formato: Brossura
  • Illustration Notes: XXII, 694 p. 493 illus.
  • Pagine Arabe: 694
  • Pagine Romane: xxii